Jcy-80b Flue Gas Comprehensive Analyzer | Flue Gas Analyzer
  • Product name锛欽cy-80b Flue Gas Comprehensive Analyzer | Flue Gas Analyzer
  • Order number锛
  • Model锛欽CY-80B
  • Stock status锛欴elivery according to contract
  • Logistics锛歜y sea, by air, by express, etc.
  • Product Introduction
  • 1. Product introduction


    The JCY-80B flue gas comprehensive analyzer adopts the positioning electrolysis method to measure the harmful gases in the flue. It can be widely used in environmental monitoring, labor protection, industrial hygiene, factories and mines and other departments to determine the concentration of harmful gases in pipeline pollution sources and to evaluate and calibrate the accuracy of continuous flue gas measurement instruments.


    2. Product parameters


    The main parameters

    parameter range

    Resolution

    Accuracy

    flue gas pressure

    0~2000Pa

    1 Pa

    鈮ぢ2%

    flue gas static pressure

    -30.00 ~ +30.00 kPa

    0.01 kPa

    鈮ぢ4 %

    Pressure before flowmeter

    -30.00 ~0.00kPa

    0.01 kPa

    鈮ぢ2.5 %

    Temperature before flowmeter

    -20.0 ~ 150.0鈩

    0.1鈩

    鈮ぢ2鈩

    flue gas temperature

    0 ~ 500鈩

    1鈩

    鈮ぢ3鈩

    Flue gas flow rate

    5-45m/s

    1m/s

    鈮ぢ5 %

    Sampling flow

    0.1L/min~2L/min, factory setting 1 L/min

    O 2 (standard)

    (0锝30)%

    0.1%

    Indication error: better than 卤2.5 %; repeatability: 鈮2.0 %; response time: 鈮90s; stability: change in indication value within 1 hour 鈮5.0 %.

    SO 2

    (0锝5700/large indication value 14000)mg/m3

    1mg/m3

    NO

    (0锝1300/large indication value 6700)mg/m3

    1mg/m3

    NO 2

    (0锝200/large indication value 2000)mg/m3

    1mg/m3

    CO

    (0锝5000/large indication value 25000)mg/m3

    1mg/m3

    CO 2

    (0锝20)%

    0.01%

    H2S _ _

    (0锝300/large indication value 1500)mg/m3

    1mg/m3

    The service life of the smoke sensor

    about 3 years in the air

    Working power

    AC220V卤10% 50Hz or DC12V (built-in)

    noise

    < 50dB(A)

    Power consumption

    <50W

    Total Weight

    about 3kg


    3. Product Features


    1. Advanced mold forming process, simple operation, small size, light weight, compact structure, easy to carry.
    2. An oxygen sensor is integrated to display the oxygen content and calculate the excess air coefficient (basic type).
    3. Automatically memorize the parameters entered each time, and use it automatically the next time the machine is turned on, realizing one-key sampling.
    4. Adopt imported wide temperature OLED display screen, automatic backlight lighting, good man-machine interface with pictures and texts, save the trouble of adjusting the contrast, and can work in ultra-low temperature and low illumination environment.
    5. The imported flow sensor is used to automatically monitor the working flow of the sampling pump, and automatically adjust the power of the sampling pump according to the pressure in the flue, so that the sampling flow is always kept constant.
    6. The measurement results of imported pressure sensors and imported electrochemical sensors are more accurate. The integrated design of electrochemical sensing and signal module, replacement of sensors does not require calibration, and has temperature and linear compensation and cross-interference correction functions to ensure measurement accuracy.
    7. It can measure the emission concentration and converted concentration of various harmful gases such as SO2, NO, NO2, CO, CO2, H2S (optional).
    8. The built-in large-capacity rechargeable battery can work continuously for more than 8 hours without AC power. After connecting the AC power, the instrument automatically charges the battery and has a real-time clock.
    9. Equipped with a hand-held flue gas pre-processor, which can dedust and dehydrate the flue gas to ensure long-term measurement accuracy (the simple sampling tube damages the sensor and causes the sensor to age in advance, and SO2 and other gases are absorbed by condensed water. cause the measurement result to be low). 10. Adopt the combination of small volume, high flow flue gas diaphragm sampling pump and electronic flowmeter to realize adjustable flow and constant current sampling.
    12. The exhaust gas upper exhaust design can effectively solve the blockage caused by the lower exhaust gas and the damage caused by the exhaust gas in the instrument.
    13. The parameters of the instrument can be directly calibrated linearly through the waterproof keyboard. A password must be entered for instrument maintenance and calibration to ensure the safety of instrument parameters.
    14. Real-time display of parameters such as direct reading dynamic pressure, static pressure, temperature, smoke temperature, flow rate, flow rate, speed, etc., and automatic measurement of atmospheric pressure.

    15. The instrument has its own storage function, which can store 10,000 sets of data, and can use micro-printing to connect RS232 to print sampling reports on site. You can also use USB memory or memory card storage, connect to a computer to print data reports.