PRODUCTS CENTER





-
Product name:Jc-M310f Multi-Parameter Analyzer -
Order number: -
Model:JC-M310F -
Stock status:Delivery according to contract -
Logistics:by sea, by air, by express, etc.
- Product Introduction
-
Product feature:
² LCD display screen, 3.5 inches.
² Multi-reading feature allows auto-read, timed-read and continuous-read.
² Automatic/Manual temperature compensation ensures accurate results.
² Auto-hold feature senses and locks the measurement endpoint.
² Data capacity of up to 500 sets for each parameter (GLP-compliant).
² Support for USB communication.
² Auto-power off feature effectively extends the battery service life.
² Reset feature automatically resumes all settings back to factory default options.
² IP65 waterproof. The portable meter is suitable for fields measurements and out door measurements.
Include:
² E-301-QC 3 in 1 pH composite electrode
² DJS-1VTC EC electrode
² DO-958-Q polarographic DO electrode
² NIST pH standard solution(4.01, 7.00, 10.01) , 50ml/vial
² 1413μS/cm EC standard solution, 50ml, 1 vial
² Electrode holder
² Silicone rubber case
² Wristbands
² Carrying Case
Model
M310F
Parameters
pH/EC/ISE/DO/Temp. (mV/pX/Resistivity/TDS/Sal./DO Saturation)
pH
Range
-2.00 to 20.00 pH
Resolution
0.1, 0.01 pH
Accuracy
±0.01 pH
Calibration Points
Up to 5
Standard Customization
Yes
Standard Recognition
NIST, GB, USA and DIN buffers
Slope Limit
Yes
mV
Range
-2000.0 to 2000.0 mV
Resolution
0.1
Accuracy
±0.3 mV or ±0.1%
pX
Range
-2.00 to 20.00 pX
Resolution
0.1, 0.01 pX
Accuracy
±0.01 pX
Calibration Points
Up to 5
ISE
Range
1.000e-9 to 9.999e+9
Units
mol/L, mmol/L, g/L, mg/L, μg/L, ppm, ppb
Resolution
Up to 4 significant digits
Accuracy
±0.5%
Calibration Points
Up to 5
Conductivity
Range
0.000 μS/cm to 500 mS/cm
Resolution
0.001 μS/cm minimum,
various with range selection
Accuracy
±1.0% FS
Reference Temperature
20, 25 ºC
Calibration Points
Up to 3
Standard Recognition
84μS/cm, 1413μS/cm, 12.88mS/cm
Resistivity
Range
5.00 Ω·cm~20.00 MΩ·cm
Resolution
0.01 Ω·cm minimum
Accuracy
±1.0% FS
TDS
Range
0.00 ppm~300 ppt
Resolution
0.01 ppm minimum, various with range selection
Accuracy
±1.0%FS
Salinity
Range
0.0~80.0 ppt
Resolution
0.1ppt
Accuracy
±2ppt
Dissolved
Oxygen Concentration
Range
0.00 to 50.00 ppm
Resolution
0.01ppm
Accuracy
±0.10ppm
Calibration Points
Air-saturated water or zero point
Barometric Compensation
Yes
Manual Salinity Factor Correction
Yes
Saturation
Range
(0.0 to 300.0)%
Resolution
0.1%
Accuracy
±2.0%
Temperature
Range
-5 to 110 ºC, 23 to 230 ºF
Unit
ºC, ºF
Resolution
0.1
Accuracy
±0.2ºC
Measurement
Reading Mode
Auto Read (Fast, Medium, Slow), Timed, Continuous
Reading Prompts
Reading, Stable, Locked
Temp. Compensation
ATC, MTC
Data management
Data Storage
500 results each
GLP Features
Yes
Inputs
pH Electrode
BNC(Q9)
DO with Temp. Probe
4-pin aviation connector
Conductivity with Temp. Probe
5-pin aviation connector
Outputs
USB
PC, printer
Display options
Backlight
Yes
Auto Shutdown
300, 600, 1200, 1800, 3600 sec., off
IP Rating
IP65
Date and Time
Yes
General
Power
Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output
Dimensions
80×225×35 mm
Weight
400g (0.88 lb)
Dimensions (Carton)
490×410×220 mm
Weight (Gross)